Corrugated sheeting is a classic and versatile profile that is complementary to both traditional and contemporary architecture. It is used for a variety of applications such as roofing, walling and fencing. 0.42BMT is commonly used for domestic applications and 0.48BMT is commonly used for industrial applications.

Corrugated is available in an unequalled range of colours and finishes including UniZinc®, UniCote®, Colorbond®, MagnaFlow™ and the luxurious UniCote® LUX range.

Features and Benefits

  • * 762mm cover and 16mm rib height
  • * Available in 0.42BMT and 0.48BMT
  • * Hi-tensile steel – strong and lightweight
  • * 5º minimum pitch
  • * Cut to length
  • * Versatility – suitable for commercial/industrial and residential roofing and wall cladding

Colours and Finishes

The UniCote® steel colour swatches above have been reproduced to represent actual product colours as accurately as possible. However, we recommend checking your chosen colour against an actual sample of the product before purchasing, as varying light conditions, different screens and limitations of the printing process may affect colour tones. Equivalent colour names listed are trademarks of Bluescope Steel Limited and used only for comparison.

The MagnaFlow™ colour swatches above have been reproduced to represent actual product colours as accurately as possible. However, we recommend checking your chosen colour against an actual sample of the product before purchasing, as varying light conditions, different screens and limitations of the printing process may affect colour tones. Equivalent colour names listed are trademarks of Bluescope Steel Limited and used only for comparison.

The UniCote® LUX swatches above have been reproduced to represent actual product finishes as accurately as possible. However, we recommend checking your chosen finish against an actual sample of the product before purchasing, as varying light conditions, different screens and limitations of the printing process may affect its appearance.

These swatches above have been reproduced to represent actual product finishes as accurately as possible. However, we recommend checking your chosen finish against an actual sample of the product before purchasing, as varying light conditions, different screens and limitations of the printing process may affect its appearance. Equivalent colour names listed are trademarks of Bluescope Steel Limited and used only for comparison.

Installation Information

  • * Ezi-Batten Corrugated sheeting should be installed into the prevailing weather
  • * Each sheet should be laid accurately to cleanly lap the adjoining roof sheet without over or under lapping
  • * Where sheeting spans exceed 900mm for roofing and 1200mm for walling, install a side lap fastener mid-span
  • * For roofing, the valleys of each corrugation need to be turned up at the crest of the roof
  • * At the completion of each days work, the roof surface needs to be cleaned to remove all traces of metal debris and swarf. Typically this is achieved by air blower, hose down or sweeping
  • * Good trade practise should be applied, such as that contained in SA HB39:2015

General Information

Zincalume® –

Aluminium / Zinc / Magnesium alloy coated steel coil, 125grams/m² coating weight.
Metallic coating conforms to AS1397:2011. Suitable for ISO9223:2012 Atmospheric
Classifications C1 – C3

Colorbond® –

Pre-painted Aluminium / Magnesium / Zinc alloy coated steel coil, 100grams/m² coating
weight. Metallic coating conforms to AS1397:2011, pre-painted finish conforms to
AS/NZS2728:2013. Suitable for ISO9223:2012 Atmospheric Classifications C1 – C3

MagnaFlow™ –

Pre-painted Zinc / Aluminium / Magnesium alloy coated steel coil, 240grams/m² coating
weight. Metallic coating conforms to AS1397:2011, pre-painted finish conforms to
AS/NZS2728:2013. Suitable for ISO9223:2012 Atmospheric Classifications C1 – C4

Sheeting max (kg/m2 of roof area)
Zincalume® Corrugated®
0.42mm BMT 4.28 4.35
0.48mm BMT 4.86 4.93

Ezi-Batten Corrugated sheeting has been assessed for suitability for use in non-cyclonic
roof and wall cladding applications in accordance to AS1562.1:2018, applicable to both
residential and commercial applications. Metallic coated materials comply with
AS1397:2011 and pre-painted materials comply with AS/NZS2728:2013. Installation of
product shall be in compliance with AS1562.1:2018 and SA HB-39:2015, National
Construction Code (NCC) and relevant QSM Technical Bulletins.

Ezi-Batten Corrugated sheeting will give excellent durability in almost all locations. It
is however important to choose the correct coating for each environment as shown in the
table below. Durability recommendations do vary based on the application of the product,
in roofing or walling installations.

Roof Sheeting – Site Exposure Condition

Suitability of coating type Mild
(ISO Category 1-2)
Moderate
(ISO Category 2)
Marine
(ISO Category 3)
Severe Marine
(ISO Category 4)
Wall cladding – distance from marine environment
Zincalume® Yes Yes No No >1km
Zincalume® Yes Yes No No >1km
Zincalume® Yes Yes No No >1km

* Severe marine begins 100 – 400m from the coast and may extend inland depending on
local conditions.

These are general guidelines only. Building location, design and aspect need to be
taken into account. To ensure warranty will be given, check with Ezi-Batten before
using in these areas.

Foot traffic limits for Ezi-Batten Corrugated sheeting are based on the accepted industry practice of designing traffic limitations on typical maintenance work. This equates to a single person with a small tool kit up to a total mass of 110kg (1.1kN load).
Walking on Ezi-Batten Corrugated profile requires that feet are placed evenly over at least two ribs. Walk as close as practical to the supports or ideally walk directly on the screw line.

Suitability of coating type Mild
(ISO Category 1-2)
Moderate
(ISO Category 2)
Marine
(ISO Category 3)
Severe Marine
(ISO Category 4)
Wall cladding – distance from marine environment
Zincalume® Yes Yes No No >1km
Zincalume® Yes Yes No No >1km
Zincalume® Yes Yes No No >1km

* Severe marine begins 100 – 400m from the coast and may extend inland depending on
local conditions.

These are general guidelines only. Building location, design and aspect need to be
taken into account. To ensure warranty will be given, check with Ezi-Batten before
using in these areas.

Due diligence needs to be applied to ensure that all materials are compatible. Corrosion may occur when incompatible materials are either in direct contact, immersed in a common electrolyte, receive inert drainage or drainage from incompatible materials.
As a general rule for metallic coated and pre-painted materials, always avoid direct contact with copper, lead, tantalised timber, Monel, uncoated steel, stainless steel and concrete/mortar.
Drainage from inert materials must not flow onto galvanised material. Inert materials include glass, aluminium, glazed ceramic tiles, pre-painted steel and metallic coated steel.
More highly corrosive environments require additional care, the effects of marine and industrial environments can extend long distances from the source and create unique corrosive challenges.
Ezi-Batten are here to assist, speak to your representative for further assistance.

  • *
    Roofing and cladding materials that are not exposed to rainfall should be washed
    down at least once every six months (more often in marine environments) to remove
    build-up of corrosive elements.
  • *
    Prior to installation, materials must be kept clean and dry. Ensure that sheeting
    packs are covered, air flow is adequate to eliminate condensation and water is not
    allowed to pond. Should materials get wet, sheeting must be separated and thoroughly
    dried.
  • *
    Sheeting should be handled with care to both avoid installer injury and damage to
    the product. Cutting of sheets must only be done with tin snips, shears or
    cold-cutting saw, so as to avoid the damage caused by abrasive cutting methods (i.e
    angle grinder).

* Roofing and cladding materials that are not exposed to rainfall should be washed down at least once every six months (more often in marine environments) to remove build-up of corrosive elements.
* Prior to installation, materials must be kept clean and dry. Ensure that sheeting packs are covered, air flow is adequate to eliminate condensation and water is not allowed to pond. Should materials get wet, sheeting must be separated and thoroughly dried.
* Sheeting should be handled with care to both avoid installer injury and damage to the product. Cutting of sheets must only be done with tin snips, shears or cold-cutting saw, so as to avoid the damage caused by abrasive cutting methods (i.e angle grinder).

Installation Information

Three Fasteners

BMT Application Span Type
Wind Class N1
Wind Class N2
Wind Class N3
0.42
Roofing
Internal
1200
1200 1200
0.42 Roofing Double 900 900 900
0.42 Roofing End 900 900 900
0.42 Walling Internal 2600 2350 2050
0.42 Walling Double 2150 1750 1550
0.42 Walling End 2150 1750 1550
0.48 Roofing Internal 1600 1600 1600
0.48 Roofing Double 1200 1200 1200
0.48 Roofing End 1200 1200 1200
0.48 Walling Internal 2700 2450 2100
0.48 Walling Double 2350 1950 1700
0.48 Walling End 2350 1950 1700

Five Fasteners

BMT Application Span Type
Wind Class N1
Wind Class N2
Wind Class N3
0.42
Roofing
Internal
1200
1200 1200
0.42 Roofing Double 900 900 900
0.42 Roofing End 900 900 900
0.42 Walling Internal 2600 2300 2100
0.42 Walling Double 2150 1900 1750
0.42 Walling End 2150 1900 1750
0.48 Roofing Internal 1600 1600 1600
0.48 Roofing Double 1200 1200 1200
0.48 Roofing End 1200 1200 1200
0.48 Walling Internal 2700 2500 2300
0.48 Walling Double 2350 2100 1900
0.48 Walling End 2350 2100 1900

Wind Pressure Limit State Capacities – 3 Fasteners per Sheet

Type Limit State Span(mm) Span (mm) Span (mm) Span (mm) Span (mm) Span (mm) Span (mm) Span (mm) Span (mm)
600
900
1200 1500 1800 2100 2400 2700 3000
Internal Serviceability 2.41 1.93 1.42 1.23 1.03 0.84 0.65 0.46 0.27
Internal Strength 10.33 9.45 6.08 5.15 4.22 3.82 3.43 2.69 1.65
Double Serviceability 2.15 1.68 1.39 1.05 0.74 0.60 0.44 0.31 0.20
Double Strength 10.33 6.83 4.52 3.91 3.30 3.18 2.53 2.01 1.58
End Serviceability 2.15 1.68 1.39 1.05 0.74 0.60 0.44 0.31 0.20
End Strength 10.33 6.83 4.52 3.91 3.30 3.18 2.53 2.01 1.58
Internal Serviceability 2.87 1.42 1.25 1.09 0.92 0.76 0.59 0.43
Internal Strength 12.43 10.03 7.18 6.37 4.50 4.08 3.66 2.99 2.15
Double Serviceability 4.12 2.07 1.39 1.15 0.91 0.72 0.56 0.39 0.31
Double Strength 11.41 9.43 7.14 5.62 4.37 3.69 3.04 2.53 2.10
End Serviceability 4.12 2.07 1.39 1.15 0.91 0.72 0.56 0.39 0.31
End Strength 11.41 9.43 7.14 5.62 4.37 3.69 3.04 2.53 2.10

Wind Pressure Limit State Capacities – 5 Fasteners per Sheet

BMT Type Limit State Span (mm) Span (mm) Span (mm) Span (mm) Span (mm) Span (mm) Span (mm) Span (mm)
600
900
1200 1500 1800 2100 2400 2700 3000
Internal Serviceability 7.00 4.79 2.60 2.20 1.50 1.00 0.69 0.50 0.27
Internal Strength 12.43 11.66 7.53 6.80 6.07 5.34 4.62 3.89 3.16
Double Serviceability 6.97 4.55 2.54 1.50 0.89 0.61 0.42 0.30 0.24
End Strength 11.41 10.50 7.25 6.80 6.07 5.26 4.35 3.60 2.98
Internal Serviceability 7.08 5.08 3.08 2.64 1.82 1.26 0.90 0.65 0.43
Internal Strength 12.43 11.12 7.89 7.09 6.28 5.47 4.66 3.85 3.04
Double Serviceability 6.97 5.08 2.99 1.82 1.18 0.79 0.54 0.36 0.23
Internal Strength 12.43 10.03 7.18 6.37 4.50 4.08 3.66 2.99 2.15
Double Serviceability 6.97 5.08 2.99 1.82 1.18 0.79 0.54 0.36 0.23
Double Strength 11.41 10.31 7.89 7.09 6.28 5.47 4.66 3.85 3.04
End Serviceability 6.97 5.08 2.99 1.82 1.18 0.79 0.54 0.36 0.23
End Strength 11.41 10.31 7.89 7.09 6.28 5.47 4.66 3.85 3.04

Table based on testing in accordance to AS1562.1:2018, AS4040.0:1992 (R2016) and AS4040.2:1992 (R2016, Amd.1 2018), to be used in conjunction with AS1170.2:2011 (R2016). Internal spans must have both end spans reduced by 20%. Roof sheets are to be fastened with minimum 12 gauge screw and wall sheets are to be fastened with minimum 10 gauge screw, having a non-conductive sealing washer and minimum corrosion coating of Class 4. Table based on fixing to minimum steel support thickness of 1.50mm BMT.

Fastener Selection

Fastening screws are to be hex head and must be fitted with a non-conductive sealing washer for both roof and wall applications. Screws must conform to AS3566 with a corrosion resistant coating to Class 4 as minimum. Use of load spreading washers for high wind zones and for the fixing of flashings is encouraged. Fastener lengths specified below are based on using 60mm blanket, thicker insulation may require increased screw lengths.

Ezi-Batten Corrugated Screws (Non-Cyclonic only)
Wind Pressure Limit State Capacities – 3 Fasteners per Sheet

Application Fixing to Timber Fixing to Steel ?1.2 Fixing to Steel ?1.2
Crest Fixed Roof 12g x 50mm Type 17 or M6 x 50mm Roof Zips® M6 x 50mm Roof Zips® or 12g x 50mm Teks® M6 x 50mm Roof Zips® (up to 1.9mm) or 12g x 50mm Teks®
Valley Fixed Wall 12g x 25mm Type 17 or 10g x 25mm Designer Head Zips® 10g x 25mm Designer Head Zips® or 10g x 16mm Teks® (over 1.0mm) 10g x 16mm Teks® or 10g x 25mm Designer Head Zips® (up to 1.9mm)

When fixing to steel section of 0.75mm BMT or less, use Type 17 or proprietary hybrid point screw. Metal self-drilling screws (such as Buildex® Teks®) should not be used in steel less than 1.0mm BMT. Buildex® Roof Zips® may be used both in steel (up to 1.9mm) and timber.

Buildex® Designer Head Zips® may be used both in steel (up to 1.9mm) and timber. Designer Head Zips® are an ideal solution for valley fixing Rollsec Corrugated, resulting in a pleasing and discrete finish.


Fastener Locations
Roofing: Three Fastener Location (internal supports)

Roofing: Five Fastener Location (end supports)


Walling: Three Fastener Location (internal supports)


Walling: Five Fastener Location (end supports)

Minimum Slope (degrees)
Total Roof Run Length = TRRL

Rainfall intensity (mm/hr) TRRL 10m TRRL 15m TRRL 20m TRRL 25m TRRL 30m TRRL 40m Max roof run length (m) at 5°min slope
150 5.5 9.1 14 19 24
175 5.0 8.4 14 20 20
200 6.6 12 19 18
225 5.0 9.1 16 16
250 5.5 12 21 14
275 7.2 16 13
300 9.1 19 12
325 12 23 11
350 5.0 14 10
375 5.5 16 9
400 6.6 19 9

Drainage capacity calculated in accordance to AS1562.1:2018